DY1S - Subminiature
DY1 - Subminiature
DY3 - Miniature/High Power
DY5 - Subminiature
DY6 - Miniature/High Power
DYL - Compact Power
DYC - Miniature Power
DAR - Automobile Use
DAR2 - PC Board Type Automobile Relay
DAR3 - High Power Automobile Relay
DYMIO - PC Board Type High-Power Relay
ORR - Reed Relay
DY5 - RELAYS
SUBMINIATURE PC BOARD RELAY
FEATURES
Low cost and highly reliable
Miniature size (11.5 X 15.5 X 10.5mm max.)
Standard terminal arrangement on 2.5mm gird
Fast response (5 msec operate time)
Contact section located opposite the terminal section and dustproof cover prevents solder flux wicking
Sealed type available
UL recognized
TYPICAL APPLICATIONS
Telecommunications equipment
Alarm devices
Control panels
Measuring instruments
Automatic warehouse control
Business machines
Vending machines
Industrial robots
Optical instruments
Medical equipment
ORDERING INFORMATION
DY5
12
Model
Coil Voltage (VDC)
Subminiature
PC Board Relay
1.5, 3, 5, 6, 9, 12, 24
COIL RATINGS
Nominal Voltage (VDC)
Coil Resistance (ohm)
Nominal Current (mA)
Pick-Up Voltage
Drop-Out Voltage
Max. Voltage
Coil Power Dissipation
% of nominal voltage
1.5
5
300
80max.
10 min.
130 max.
0.45W
3
20
150
5
56
89.3
6
80
75
9
180
50
12
320
37.5
24
1,280
18.8
Note: The rated current and resistance are measured at a coil temperature of 20°C with tolerances of ±10%
CONTACT RATINGS
Load
Resistive load
(cos
f
=1)
Inductive load
(cos
f
=0.4, L/R=7mS)
Rated Load
2A 110V AC, 2A 24V DC
1A 110V AC, 1A 24V DC
Carry Current
2A
Max. Voltage
250V AC 60V DC
Max. Switching Current
2A
Max. Switching Capacity
220VA, 48W
110VA, 24W
Min. Permissible Load (Ref. Value)
5VDC, 5mA
CHARACTERISTICS
Contact arrangement
1 Form C
Contact Material
Silver Alloy
Initial Contact Resistance
100m ohm max.
Coil Power Dissipation
0.45W
Coil Temperature Rise
45 deg. max.
Insulation Resistance
100M ohm min. (at 500 VDC)
Breakdown Voltage
500V AC (50/60Hz) for 1 minute
Operate Time
5 msec max.
Release Time
5 msec max.
Expected Life
Mechanical 5,000,000 operations min. (at 18,000 ops/hour)
Electrical 100,000 operations min.
Shock Resistance
Functional 10G's
Destructive 100G's
Vibration Resistance
Functional 10 to 55Hz (Double amplitude 3.3mm)
Destructive 10 to 55Hz (Double amplitude 3.3mm)
Operating Frequency
Mechanical 18,000 operations/hour
Electrical 1,800 operations/hour
Ambient Temperature
Standard : -25 to +55°C, High sensitive : -25 to +65°C
Humidity
45% to 85% RH
Unit Weight
Approx. 3.7 gr.
Note: The data shown above are of initial value.
DIMENSIONS
Terminal arrangement/internal
connections (bottom view)
Mounting holes (bottom view)
Tolerance : ±0.1
NOTE: ALL DIMENSIONS SHOWN IN THIS CATALOG ARE IN UNITS OF MILLIMETERS.
To convert millimeters into inches multiply by 0.03937.
To convert grams into ounces multiply by 0.03527.
Contents
Relay Selector Chart
Glossary
Ripple Factor
Kinds of Load
Contact Protection Circuits
Relays in Electronic Circuits
Know-how of Circuit Design
Mounting Direction for Relays
Soldering and Cleaning Recommendations
Representative Latching Relay Circuits
Standard Terms:
Check/Money Order
Net 30
Credit Card
Minimum Order:
$100.00
Wholesale/OEM
Distributed by
CeeJay
16475 Canyon Hills Road #3
Chino Hills, California 91709
Tel: (714) 572-2169
Fax: (714) 572-2169
E-mail:
sales@ceejay.com
© Copyright 1997 - 2004, CeeJay
All rights reserved.