| DYC magnetic latching relays are particularly suitable for various
vending machines, remote control devices, parking meters, conveyor, NC
machinery, etc. |
 |
| COIL RATINGS |
 |
 |
| Rated Voltage (V) |
AC |
DC |
| 6 |
12 |
24 |
50 |
100 |
110 |
120 |
6 |
12 |
24 |
| Set Coil |
Rated Current (mA) |
50Hz |
146 |
57 |
27.4 |
14 |
7.1 |
7.8 |
5.8 |
230 |
110 |
52 |
| 60Hz |
142 |
56 |
26.4 |
13.4 |
6.9 |
7.6 |
5.7 |
| Coil Resistance (ohm) |
13 |
72 |
320 |
1,400 |
5,400 |
5,400 |
8,300 |
26 |
110 |
470 |
| Coil Inductance (ref. value) (H) |
Armature OFF |
- |
- |
| Reset Coil |
Rated Current (mA) |
50Hz |
68 |
39 |
18.6 |
3.5 |
3.5 |
3.8 |
3.5 |
100 |
50 |
25 |
| 60Hz |
| Coil Resistance (ohm) |
32 |
130 |
550 |
3,000 |
3,000 |
3,000 |
3,000 |
60 |
235 |
940 |
| Coil Inductance (ref. value) (H) |
Armature ON |
- |
- |
| Must Set Voltage |
% of rated voltage |
80 max. |
| Must Reset Voltage |
80 max. |
| Maximum Voltage |
110 max. |
| Power Consumption (VA, W) |
Set Coil |
Approx. 0.6 to 0.9 |
Approx. 1.3 |
| Reset Coil |
Approx. 0.2 to 0.5 |
Approx. 0.6 |
Note:
- The rated current and coil resistance are measured at a coil
temperature of 20°C with tolerances of +15%, -20% for AC rated
current and 15% for DC rated current, and 15% for rated coil
resistance.
- The rated current and performance characteristics are measured at
a coil temperature of 5 to 35°C
|
|
 |
| CONTACT RATINGS |
 |
 |
| Load |
Resistive load
(p.f.=1) |
Inductive load
(p.f.=0.4, L/R=7 msec) |
| Rated Load |
7A 220V AC,
7A 24V DC |
3A 220V AC,
3A 24V DC |
| Carry Current |
7A |
| Max. Operating Voltage |
250V AC 125V DC |
| Max. Operating Current |
7A |
3A |
| Max. Switching Capacity |
1,540VA, 168W |
660VA, 72W |
| Minimum Permissible Load (Reference
Value) |
5VDC/100mA |
|
 |
| CHARACTERISTICS |
 |
 |
| Contact Resistance |
50m ohm max. |
| Operate (Set) Time |
AC : 30 msec max. DC : 15 msec max. |
| Release (Reset) Time |
AC : 30 msec max. DC : 15 msec max. |
| Operating Frequency |
Mechanically : 18,000 operations/hour
Under rated load : 1,800
operations/hour |
| Insulation Resistance |
100M ohm min. (at 500V DC) |
| Breakdown Voltage |
1,500V AC, 50/60Hz for 1 minute (1,000V AC between non-continuous
contacts, and between set and reset coils) |
| Vibration Resistance |
Mechanical durability : 10 to 55Hz : 1.0mm double amplitude
Malfunction
durability : 10 to 55Hz : 1.0mm double amplitude |
| Shock Resistance |
Mechanical durability : 1,000m/s2 (approx. 100G's)
Malfunction
durability : 100m/s2 (approx. 10G's) |
| Ambient Temperature |
Operating : -10 to +60°C |
| Humidity |
45 to 85% RH |
| Expected Life |
Mechanically : 100,000,000 operations min. (at operating frequency
of 18,000 operations/hour)
Electrically : 200,000 operations min.
(at rated load) |
| Unit Weight |
Approx. 30 gr. |
|
Note: The data shown above are of initial value.
|
|
 |
| CHARACTERISTIC DATA |
 |
 |
Electrical Service Life (Resistive Load)
DYC1,
DYC2, DYC3 |
Electrical Service Life (Inductive Load)
DYC1,
DYC2, DYC3 |
 |
 |
Max. Switching Capacity
DYC1, DYC2,
DYC3 |
Max. Switching Capacity
DYC4 |
 |
 |
Electrical Service Life (Resistive Load)
DYC4 |
Electrical Service Life (Inductive Load)
DYC4 |
 |
 |
|
 |
| DIMENSIONS |
 |
 |
| DYC2S-K |
DYC2P-K |
 |
 |
| Mounting Holes |
 |
| Terminal Arrangement/Internal Connection
(Bottom View) |
 |
 |
NOTES:
- R is a resistor for ampere-turn compensation, and is
incorporated in the relays rated at 50V AC or above.
- Pay attention to the polarity of the set and reset coils, as
incorrect connection of positive and negative terminals will
result in malfunctioning of the relay.
|
|
 |
| HINTS ON CORRECT USE |
 |
 |
| When using the relay rated at 100 or 120V AC at a
supply voltage of 200 or 240V AC, be sure to connect external
resistors Rs and Rr to the relay. |

Power
supply for reset coil |
110V
Rs: 7kW 1.5w
Rr:
14kW 1w |
120V
10kW 1.5w
17kW
1w |
|
| |
NOTE: ALL DIMENSIONS SHOWN IN THIS CATALOG ARE IN UNITS OF
MILLIMETERS.
To convert millimeters into inches multiply by 0.03937.
To
convert grams into ounces multiply by 0.03527. |
|