DAR3-RELAYS

POWER AUTOMOBILE RELAY

DAR3 relaysblue square FEATURES

blue square TYPICAL APPLICATIONS

blue square ORDERING INFORMATION

DAR3 1 F ---------- R ---------- B ---------- 12V
 lines
Contact Arrangement Protective Construction Classification of Types Mounting Classification Coil Voltage (DC)
1a : 1 Form A
1 : 1 Form C
Nil : Sealed type
F : Flux-resistant type
Nil : Standard type
D : with diode inside
R : with resistor inside
Nil : Quick connect type
B : Bracket type
12V

blue square CONTACT SPECIFICATION

Type 12V coil voltage
Arrangement 1 Form A, 1 Form C
Initial Voltage Drop N.O. : Max. 0.5V (at 40A 12V DC)
N.C. : Max. 0.45V (at 30A 12V DC)
Contact Material Silver alloy
Rating (Resistive Load)  
  Nominal Switching Capacity N.O. : 40A 14V DC
N.C. : 30A 14V DC
  Max. Switching Power N.O. : 560W
N.C. : 420W
  Max. Switching Voltage 16V DC
  Max. Switching Current See Contact Rating table
Expected Life (Min. Ope.)  
  Mechanical (at 120 cpm) 106
  Electrical (at rated load operating frequency 2 sec. ON, 2 sec. OFF) 105
(Sealed type : 5 X 104)

blue square COIL SPECIFICATION

Nominal Voltage 12V DC
Coil Resistance 70W ± 10%
Must Pick-Up Voltage 9.9V DC
Must Drop-Out Voltage 1.2V DC
Must Applicable Voltage 15.60V DC
Power Consumption 2.60W

blue square CONTACT RATING

  12V Coil Voltage
Form A Form C
N.O. N.C.
Max. Carry Current 40A 40A 30A
Max. Make Current 100A 100A 60A
Max. Break Current 40A 40A 30A

blue square CHARACTERISTICS

Ambient Temperature -90°C ~ +80°C
Vibration Test 10 - 55Hz, 1.5mm
Shock Test 10G, Approx
Humidity 45% ~ 85% RH
Insulation Resistance 100MW (500V DC 1 min.)
Dielectric Withstanding Strength between contacts : 500V AC 50/60Hz 1 min.
between contacts and coil : 500V AC 50/60Hz 1 min.
Operate Time ³ 10.00mS
Release Time £ 9.00mS
Unit Weight Approx. 30.0 gr.

blue square DIMENSIONS & SCHEMATICS

Bracket Type
DAR3 relay Drawing
diagram diagram
digram Schematic (Bottom View)
If diode is used, term 86 is to be positive
diagram
*Not used on 1 Form A type.
General tolerance: ±0.3


Quick connect type
DAR3 relay
diagram diagram
diagram Schematic (Bottom View)
If diode is used, term 86 is to be positive
diagram
*Not used on 1 Form A type.
General tolerance: ±0.3

NOTE: ALL DIMENSIONS SHOWN IN THIS CATALOG ARE IN UNITS OF MILLIMETERS.
To convert millimeters into inches multiply by 0.03937.
To convert grams into ounces multiply by 0.03527.

blue square GRAPHICAL DATA

blue square NOTES

  1. Avoid using in the location where there is organic gas such as SO2 gas and H2S gas. Note that switching contact in the silicon atmosphere may result in contact failure.
  2. The switching voltage and current to the contact should not exceed the rated value.
  3. The rated contact capacity and life are typical values. Since contact conditions and life vary depending on kinds of loads and other conditions, please examine them through actual conditions.
  4. Relays should be used within the rated ambient temperature.