DAR3-RELAYS
DATA

  1. Maximum value for switching capacity
    Tested sample: DA3 1F-12V
    No. of operations: 105

    graph


    1. Coil temperature rise (resistive)
      Tested sample: DA3 1F-12V, 6 pcs

      Ambient temperature: 20°C, 85°C, 125°C
      68°F, 185°F, 257°F

      Contact carrying current: 40A
      Coil applied voltage: 12V, 14V, 16V DC

      graph


    2. Coil temperature rise (resistive)
      Tested sample: DA3 1F-12V, 6 pcs
      Ambient temperature: 20°C, 68°F
      Contact carrying current: 20A, 30A, 35A, 40A
      coil applied voltage: 12V, 14V, 16V DC

      graph


  2. Distribution of operate/release time
    (at nominal voltage)
    DA3 1F-12V, 100 pcs
    Ambient temperature: 22°C, 72°F
    Operate time
    graph

    Release time
    graph


  3. Distribution of pick-up/drop-out voltage
    Tested sample: DA3 1F-12V, 100 pcs.

    Pick-up voltage
    graph


    Distribution of pick-up/drop-out voltage
    Tested sample: DA3 1F-12V, 100 pcs.

    Drop-out voltage
    graph


  4. Distribution of voltage drop
    Tested sample: DA3 1F-12V, 100 pcs.
    Tested method: at 10A voltage drop

    N.C. contact
    graph

    N.O. contact
    graph


  5. Free-fall test
    Test conditions:
    Drop height: 2 meters to concrete surface
    Drop direction: 6 directions, each 1 drop
    sample: DA3
    Quantity: 6 pcs. 1F-12V


    diagram diagram diagram diagram
    Sample No. 1
    direction
    Sample No. 2
    direction
    Sample No. 3
    direction
    Sample No. 4
    direction
    diagram diagram
    Sample No. 5 direction Sample No. 6 direction


    Test result: No abnormality was observed.
    Sample No. No. of Operations Pick-up Voltage, V Drop-out Voltage, V Contact Resistance, mW Insulation Resistance Breakdown voltage
    N.C. N.O.
    1 Initial
    (at 28°C)
    5.2 1.8 1.9 1.5 good good
    2 5.2 1.9 1.5 1.7 good good
    3 4.9 1.8 1.6 1.9 good good
    4 5.1 1.8 1.7 2.6 good good
    5 5.2 1.8 1.9 1.7 good good
    6 5.3 2.1 2.0 1.5 good good
    1 After
    (at 28°C)
    4.7 1.6 1.7 1.4 good good
    2 4.9 1.8 2.2 1.7 good good
    3 4.4 1.5 2.5 1.6 good good
    4 4.7 1.6 2.2 2.3 good good
    5 4.8 1.6 2.5 1.6 good good
    6 4.7 1.7 1.7 1.6 good good
    Contact resistance: contact voltage drop (10 A)
    Insulation resistance: 20 MW at 500V DC
    Breakdown voltage: Between open contacts: 500 Vrms
    Between contacts and coil: 500 Vrms.

  6. Ambient temperature characteristics
    Tested sample: DA3 1F-12V, 6 pcs.


    graph
Contents
 
Relay Selector Chart
  Glossary
  Ripple Factor
  Kinds of Load
  Contact Protection Circuits
Relays in Electronic Circuits
  Know-how of Circuit Design
  Mounting Direction for Relays
  Soldering and Cleaning Recommendations
  Representative Latching Relay Circuits
 
Standard Terms: Check/Money Order
Net 30
Credit Card
Minimum Order: $100.00
Wholesale/OEM
Master Card Visa
American Express Discover
 
Distributed by
CeeJay16475 Canyon Hills Road #3Chino Hills, California 91709
Tel: (714) 572-2169Fax: (714) 572-2169E-mail: sales@ceejay.com
© Copyright 1997 - 2004, CeeJay
All rights reserved.